2 PACKS OF 6 FILES EACH FOR Rs.1100/-.
Offer valid till stocks last. Do not miss the offer. Buy Now.
HEALIX PRO GOLD ROTARY FILES are Made in India Control Memory NiTI Rotary files. They are heat treated files.HEALIX CONMEM PRO GOLD ROTARY FILES are rotary files for conducting root canal treatment.It belongs to the third generation of Rotary Endodontic Instruments.It is extremely simply to use.These files help in cleaning and shaping of the root canal complex in accordance with Schilders objectives. It requires minimal effort and provides the clinician with excellent results.These are available in 21mm and 25mm.
HEALIX PRO GOLD ROTARY FILES with Controlled Memory are up to 300% more resistant to cyclical fatigue compared to other NiTi files* which substantially helps reducing the incidence of file separation.
No rebound + Extreme flexibility= Superior canal tracking
These files have been manufactured utilizing a unique process that controls the material’s memory, making the files extremely flexible but without the shape memory of other NiTi files. This gives the file the ability to follow the anatomy of the canal very closely, reducing the risk of ledging, transportation or perforation.
Regains shape after sterilization = Multi-use
The shape and strength of files with straightened spirals can be restored during autoclave and reused. Files not returning to original shape should be discarded.
Healix® CONMEM PRO GOLD ROTARY FILES can be used with crown-down, step-back or our recommended single length technique.
Step by step instructions to use these rotary files:
Sx-Golden, S1-Purple, S2-White,F1-Yellow,F2-Red,F3-Blue
Step 1: Use manual K-File Preparation upto numbers #20 K-File. Create straight-line access to the canal orifice(s) with emphasis on flaring, flattening, and finishing the internal axial walls.
Step 2: Start the Endomotor (preferable Healix Endomatic Endomotor). Use the Sx File. Set Speed to 300 rpm and Torque 4.8 ncm or 48 mncm. Conduct orifice opener and create straight line access to the canal orifice with emphasis on flaring, flattening, and finishing the internal axial walls.
Step 3: Use S1 File.Set torque to 4.8 or 48. Take the S1 file -4 of the working length. Eg. if Apex is 20, go till 16.Use BRUSH AND FOLLOW MOTION TECHNIQUE.
Step 4: Use S2 At Torque of 1.5 ncm or 15mnm. Go full working length. Use BRUSH AND FOLLOW MOTION
Step by step instructions to use these rotary files:
Sx-Golden, S1-Purple, S2-White,F1-Yellow,F2-Red,F3-Blue
Step 1: Use manual K-File Preparation upto numbers #20 K-File. Create straight-line access to the canal orifice(s) with emphasis on flaring, flattening, and finishing the internal axial walls.
Step 2: Start the Endomotor (preferable Healix Endomatic Endomotor). Use the Sx File. Set Speed to 300 rpm and Torque 4.8 ncm or 48 mncm. Conduct orifice opener and create straight line access to the canal orifice with emphasis on flaring, flattening, and finishing the internal axial walls.
Step 3: Use S1 File.Set torque to 4.8 or 48. Take the S1 file -4 of the working length. Eg. if Apex is 20, go till 16.Use BRUSH AND FOLLOW MOTION TECHNIQUE.
Step 4: Use S2 At Torque of 1.5 ncm or 15mnm. Go full working length. Use BRUSH AND FOLLOW MOTION
TECHNIQUE. S1 and S2 will clean the 1/3 and 2/3 of Coronal Area of Tooth Structure
Step 5: Use F1,F2,F3 as Finishing file which cleans the 1/3 and 2/3 of apical area. Below are the Torque to use for F1 F2 and F3. For these Finishing Files, FOLLOW AND BRUSH MOTION TECHNIQUE needs to be followed.
Step 5: Obturate using any Gutta Percha Points (GP Points) with Variable Tapered (F1,F2,F3)
Speed and Torque Setting for Healix Rotary files:
Instructions | Torque for Endomotors | ||
File Type | Speed | Healix | Others |
Sx | 300 | 48 mnm | 4.8 ncm |
S1 | 300 | 48 mnm | 4.8 ncm |
S2 | 300 | 15 mnm | 1.5ncm |
F1 | 300 | 15 mnm | 1.5 ncm |
F2 | 300 | 30 mnm | 3.0 ncm |
F3 | 300 | 30 mnm | 3.0 ncm |
Why should we use HEALIX CONMEM PRO GOLD ROTARY FILES?
To replace the use of hand files during initial root canal procedure.
Enhanced performance of rotary file system shortens treatment time through use of fewer files per case, allowing for safe, efficient, conservative root canal treatment
These files feature a unique cross section design that combines high efficiency and flexibility while being safe and resistant to fracture.
Unprecendented Flexibility, strength & cutting efficiency
Ease mechanical preparation of the root canal
New comers to endodontics can be quickly & reliably achieve the results.
Root canal system is highly complex & a practitioner may encounter varied type of anatomies
Heat treatment reduces the cutting efficiency of the blades. Also, the flutes of these files open up as stress levels are encountered in the canal resulting in increased preparation time & apical extrusion of debris.
WHAT IS CONTROLLED MEMORY FILE SYSTEM?
- Controlled Memory NiTi Technology™ increases file strength and its flexibility. This results up to 350% greater resistance to cyclic fatigue stresses. Thus reducing the chances of file breakages.
- Controlled Memory NiTi Technology allows natural canal tracking and files can be pre-bent if needed. Typically the fluted portion of the file will straighten out or unwind before separation occurs.
Features
1) Cyclic Resistant
350% more resistant to cyclic fatigue
Improved Resistant, cyclic fatigue resistance time
Triangular cross section: Sharp cutting edges
2) Gold Treated
Advanced memory alloy tech with elegant dark gold color
Controlled memory files
Gold thermal treatment: Enhances cutting efficiency
3) High Flexibility
Extreme Flexibility: To negotiate any canal
Super – flexible gold alloy
4) Tip
Advanced Tip Process, Avoid Forming Steps
Safety Tip: Non-Cutting tip to minimize apical transportation
5) Rust – free
Corrosion Resistant
6) Disinfection
Autoclavable
Packing
Pack of 6 Nos Healix Control Memory Niti Files
Healix Conmem Pro Gold Rotary Files | Sx-F3 | NiTi Files - PACK OF 2 OFFER!
- Control Memory NiTI Files
- These are variable tapered Endodontic Rotary Files
- Lengths available – 21mm and 25mm.
- Sizes available – Coronal flaring, Sx,S1,S2,F1,F2,F3
- No rebound + Extreme flexibility= Superior canal tracking